Instrument reliability, compliance, ease-of-use, stability and accuracy are key factors for customers to consider, when they need to select a Combustion Analyzer to report accurate total sulfur data to their (internal) customers. In the
field of petroleum industry, the analysis of automotive fuels is most routine and drives laboratories to automation and fast reporting of precise data day-in-day out. The use of round robin or proficiency testing data are also a tool to proof that the existing analyzer condition fits within the scope of the method and assure the
reported data are within the confidence limits.

This Application Note shows the long-term performance of the NEXIS VP model Total Sulfur Analyzer for a set of gasoline and diesel fuel samples based on a 21-days trial to determine the precision of the obtained results in compliance to ASTM D5453, ISO 20846 methods and the TIER 3 program. The obtained data from this test also indicate the stability of the instrument configuration without recalibration of the detector or perform any maintenance of
the analyzer. This also can be supported with so-called Shewart plots generated through the instrument operating software (NEXIS LINK), which enables customers to optimize their QC operation.

Our Impact

EST Analytical has been helping labs achieve their analytical goals for over 30 years. Our vision is to engineer reliable laboratory instruments that enable partners to make the world a better place.

To help labs excel we offer Application Notes across our entire product line. They are a resource that explains the technology, performance, and abilities of our products as used against certain methodologies and or applications.

Whether your needs center around a USEPA method, an ASTM Standard, or a sample matrix-based outcome EST has you covered. If you don’t see the technical direction you need, simply contact us. We also offer sample analysis in our onsite Applications Lab.